Sign in →

Test Code N.LH LUTEINIZING HORMONE

Important Note

SERUM TUBE ONLY- SST

Methodology

Automated Chemistry Analyzer

Specimen Requirements

Serum or Plasma

Container: SST tube ONLY

Specimen Collection: 1 mL (minimum 0.5 mL)

  1. Allow specimen to clot completely. Separate serum (SST) from cells within 24 hours and transport refrigerated.
  2. Properly label tube with patient's name, DOB, requisition number and type of tube, i.e. SST.

 

Specimen Transport/Stability

Refrigerated: 24 hours on gel, 7 days poured off

Specimen Rejection

1. Grossly hemolyzed

2.  Wrong type of tube

3. Lipemic samples

Maximum Laboratory Time

1 - 2 days

Reference Ranges

LH         mIU/mL 
Males        0.6 - 12.1
Females  
     Follicular        1.8 - 11.8
     Mid-cycle        7.6 - 89.1
     Luteal        0.6 - 14.0
     Post menopausal        5.2 - 62.0

 

 

 

 

 

Day(s) Test Set Up

Daily

Test Classification and CPT Coding

83002