Test Code N.LH LUTEINIZING HORMONE
Methodology
Automated Chemistry Analyzer
Specimen Requirements
Serum or Plasma
Container: SST tube ONLY
Specimen Collection: 1 mL (minimum 0.5 mL)
- Allow specimen to clot completely. Separate serum (SST) from cells within 24 hours and transport refrigerated.
- Properly label tube with patient's name, DOB, requisition number and type of tube, i.e. SST.
Specimen Rejection
1. Grossly hemolyzed
2. Wrong type of tube
3. Lipemic samples
Maximum Laboratory Time
1 - 2 days
Specimen Transport/Stability
Refrigerated: 24 hours on gel, 7 days poured off
Test Classification and CPT Coding
83002
Day(s) Test Set Up
Daily
Reference Ranges
LH | mIU/mL |
Males | 0.6 - 12.1 |
Females | |
Follicular | 1.8 - 11.8 |
Mid-cycle | 7.6 - 89.1 |
Luteal | 0.6 - 14.0 |
Post menopausal | 5.2 - 62.0 |