Sign in →

Test Code HEMATOCRIT HEMATOCRIT

Important Note

Microtainers must be filled to second mark.

Additional Codes

HEMATOCRIT

Methodology

Automated Hematology Analyzer

Specimen Requirements

EDTA Whole Blood

Container: Lavender top tube (EDTA)

Specimen Collection: Fill tube to appropriate line; Microtainers must be filled to SECOND mark

  1. Fill tube to appropriate line.
  2. Prefer to receive specimen within 12 hours of collection.
  3. Prefer specimen to be stored and transported refrigerated.

Specimen Transport/Stability

Refrigerate

Specimen Rejection

1. Clotted specimen

2. Hemolyzed specimen

3. Exceed stability requirements

4. Underfilled tube

5. Unlabeled specimen

Maximum Laboratory Time

24 - 48 hours

Reference Ranges

Hematocrit               %  
Newborn       53.6 - 66.4
1 wk       42.5 - 62.5
1 mo       35.0 - 49.0
3 mos       30.0 - 42.0
6 mos       30.5 - 40.5
1 yr       30.0 - 41.0
7 yrs       34.0 - 40.0
15 yrs    F       38.0 - 47.0
              M       40.0 - 54.0

 

Day(s) Test Set Up

Daily

Test Classification and CPT Coding

85014