Test Code GLU.CHAL GLUCOSE TOLERANCE CHALLENGE, 1 HR
Additional Codes
N.GLUCHAL
Methodology
Automated Chemistry Analyzer
Specimen Requirements
Serum or Plasma
Container: SST tube or Lithium heparin plasma (green top tube)
Specimen Collection: 1 mL each specimen (minimum 0.5 mL each specimen)
- Draw fasting specimen just prior to 50 gram glucose load. Draw other specimen in 1 hour.
- Clearly label each specimen with time of draw.
- Allow specimen to clot completely if a serum (SST) was used for the draw.
- Separate serum (SST) or plasma (Lithium Heparin) from cells within 24 hours and transport refrigerated. If a red top tube is collected, separate serum from cells within 2 hours and place in separate plastic tube and cap immediately.
- Properly label specimen with patient's name, DOB, requisition number and type of tube drawn i.e. GREEN.
Alternate Specimens: Gray top (Sodium Fluoride)
Specimen Transport/Stability
Refrigerated: 24 hours on gel, 7 days poured off
Specimen Rejection
1. Clotted specimen
2. Exceeding stability requirements
3. Unlabeled specimen
Maximum Laboratory Time
24 - 48 hours
Reference Ranges
Glucose 1 HR | mg/dL |
< 140 |
Day(s) Test Set Up
Daily
Test Classification and CPT Coding
82950