Test Code CARB. CARBAMAZEPINE (TEGRETOL)
Additional Codes
TEG
Methodology
ALINITY Automated Chemistry Analyzer
Specimen Requirements
Serum
Container: Red top tube
Specimen Collection: 1 mL (minimum 0.5 mL)
- Separate serum from cells within 2 hours and place in separate plastic tube and cap immediately.
- Properly label tube with patient's name, DOB, requisition number and type of tube, i.e. RED.
Alternate Specimens: Lithium heparin plasma (green top tube); Lavender top tube EDTA plasma
Specimen Transport/Stability
Refrigerated: 2 hours on cells, 7 days poured off
Specimen Rejection
1. Clotted specimen
2. Exceeding stability requirements
3. Unlabeled specimen
Maximum Laboratory Time
24 - 48 hours
Reference Ranges
Carbamazepine | ug/ml |
Therapeutic | 6.0 - 10.0 |
CRITICAL VALUE | REFER TO LH-W CRITICAL VALUES POLICY |
Day(s) Test Set Up
Daily
Test Classification and CPT Coding
80156