Test Code A1ALC Alpha-1-Antitrypsin Proteotype S/Z, LC-MS/MS, Serum
Reporting Name
A1AT Proteotype S/Z, LC-MS/MS, SUseful For
Identification of homozygous and heterozygous S and Z proteotypes of alpha-1-antitrypsin deficiency
Method Name
A1ASZ: Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
AATP: Nephelometry
A1APR: Isoelectric Focusing
Performing Laboratory

Specimen Type
SerumSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1.25 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Reject Due To
Gross hemolysis | OK |
Gross lipemia | Reject |
Gross icterus | OK |
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 28 days |
Ambient | 28 days | |
Frozen | 28 days |
Reference Values
ALPHA-1-ANTITRYPSIN:
100-190 mg/dL
ALPHA-1-ANTITRYPSIN PROTEOTYPE:
Negative for S and Z phenotype (Non S Non Z)
Day(s) Performed
Monday, Thursday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82103
82542
82104 (if appropriate)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
A1ALC | A1AT Proteotype S/Z, LC-MS/MS, S | 102082-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
AATP | Alpha-1-Antitrypsin, S | 6771-0 |
34855 | A1AT Proteotype S/Z, LC-MS/MS | 49244-7 |
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
A1ASZ | A1AT Proteotype S/Z, LC-MS/MS | No | Yes |
AATP | Alpha-1-Antitrypsin, S | Yes, (order AAT) | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
A1APR | Alpha-1-Antitrypsin Phenotype, S | Yes, (order A1APP) | No |
Testing Algorithm
If the mass spectrometry proteotype and quantitative serum level are discordant, then phenotyping will be added and performed at an additional charge.
For more information see Alpha-1-Antitrypsin-A Comprehensive Testing Algorithm
Special Instructions
Report Available
7 to 14 daysForms
If not ordering electronically, complete, print, and send a Gastroenterology and Hepatology Test Request (T728) with the specimen.